How to properly prepare an estimate for electrical work 


Estimates and prices for electrical installation work

Prices for electrical installation work are characterized by great variety and a wide range of application options.
In this regard, the estimate for electrical installation work may include a huge variety of prices, which must be justified by the requirements of the work project at any construction site. The estimate for electrical installation work, as a rule, is compiled using the prices for electrical installation work from the 8th installation collection of estimate and regulatory bases GESN, FER and TER.

In addition, a sample estimate for electrical installation work in Excel, or in another convenient format, may contain standards from 33 construction collections of the same regulatory frameworks. Among other things, repair or dismantling work on electrical networks can be assessed using the standards from the collection 67 of the repair and construction part.

Who has the most stable prices for electrical installation work?

In newspapers, magazines, and social networks, specialists offer their services everywhere. Firms post a price list for electrical installation work on their websites; in each company, prices for electrical installation are posted next to the manager, and single craftsmen negotiate the price over the phone or in a personal meeting. If in the first and second cases you know exactly the cost of electrical installation work for the Moscow location (the price list is approved and signed), and you can calculate your family budget, then in the third option no one will give you a 100% guarantee that a single electrician will not add an additional amount at final settlement. Not every customer knows what exactly is included in electrical installation, but the invited private trader is unlikely to have a price list for the services. Therefore, he can set a price that will exceed the cost of electrical installation work several times over the 2021 price list of a specialized company.

It is also worth paying attention to the material the private trader uses and the quality guarantee. In this case, you have an oral agreement that cannot be confirmed by anything if necessary.

And having in your hands or before your eyes the prices for electrical installation work 2021 in Moscow from a specialized company, you already know approximately what type of work you are paying money for. From the moment you receive the check or sign the contract, you receive specialized support for the entire warranty period.

In addition, the price list always indicates prices for electrical installation work in Moscow 2021 and contains a list of materials. You can choose exactly what you think is necessary. Any company values ​​its reputation and supplies only from trusted contractors. And private owners most often take cheap materials to reduce their costs.

When choosing a company where you want to apply, you should pay attention to the equipment that specialists will use. Electrical installation work price list 2021 Moscow contains a list of services and devices we provide

It is posted in the public domain, and you can make sure that our prices for electrical installation work 2021 are quite affordable and not high.

But at the same time the quality does not suffer at all. After all, the consumer cares not only about the cost of electrical work and the price, but also about the qualifications of the employees. We employ only trained personnel who have sufficient work experience, who can find a way out of even the most difficult situations, guaranteeing high quality, as they are confident in their abilities and knowledge.

All your wishes will be taken into account. Uninterrupted operation of the power line of an apartment, home or office is guaranteed. We will carry out high-quality electrical installation at the same price as you

Collection of GESNm08 in estimates for electrical installation work of switchgears

As noted above, many estimates for electrical installation work are drawn up on the basis of the 8th installation collection of GESN and FER. This is due to the fact that most of the necessary standards used in determining the cost of EMR are contained in the specified collection.

At the same time, what is necessary in this case are not only the obvious prices of GESN for electrical installation work on laying cables or installing sockets and switches, but in general prices for the installation of all possible materials and equipment for the installation and full functioning of electrical networks. For example, prices for the installation of switchgears and substations.

Standards for the installation of switchgears and substations of various types are found in section 1 of the collection 8 of the State Electrical Service for electrical installation work. At the same time, within the specified department it is possible to select prices for open and closed switchgears, converter devices, battery installations, etc.

So, for example, an estimate for electrics using the standard code GESNm08-01-002-02 will include the installation of three-phase linear transformers 10 kV, and the standard GESNm08-01-102-01 means that the estimate form takes into account the installation of control cabinets and regulation.

If it is necessary to apply a price in the estimate for an electromagnetic lock or for installing a button, then the most suitable in this case will be one of the norms in the table GESNm08-01-081. At the same time, the installation of measuring and protection devices in estimate form is taken into account using the table GESNm08-01-080.

In addition, it should be noted that since, on the basis of the state elemental estimate standards of GESN, standards are developed in other estimate and regulatory bases, it is logical that the FERm08 or TERm08 collections for electrical installation work include standards with similar codes.

How much does it cost to install sockets and switches?

For each electrical work performed, you have to pay a separate fee. Therefore, installing sockets with switches is also worth the money.

So, the cost of installing a socket and switch for one piece:

  • Installation of an external socket or switch, cost about 450 rubles;
  • Installing an internal socket or switch will cost 750 rubles.

The installation of sockets and switches does not include the installation of holes for socket boxes. Their cost is calculated separately. A hole for a socket box in concrete costs about 450 rubles, in a brick wall 350 rubles, and in plasterboard - 250 rubles.

Prices for electrical installation of sewerage and electricity networks

An example of an estimate for temporary power supply to a construction site, as well as an example of an estimate for the installation of external electrical networks, as well as wiring in buildings and structures, contains mainly the standards from Section 2 of the GESNm08 collection.

Figure 1 shows an example of an estimate for electrical installation work using standards from the specified collection. It should be noted that the standards are applied from section 1, which combines the standards for the installation of cable lines up to 500 kV.

Figure 1. Example of an estimate for electrical work

In addition to installing a cable in a trench, the cost of which is determined using the GESNm08-02-141-01 standard, the sample estimate for electrical installation work in Excel in Figure 1 also includes other prices directly related to the installation of cable lines.

Thus, position 1 in the above electrical estimate takes into account the installation of a bed for cable lines. This type of work is assessed using the standard GESNm08-02-142-01.

Another job involved in laying cable in a trench is covering the cable with various materials to protect the cable route. In the sample estimate for electrical installation work in Figure 1, the GESNm08-02-143-01 standard is used, which takes into account covering one cable with brick.

However, based on the standards from table GESNm08-02-143, it is possible to draw up a sample estimate for electrical installation work in 2019, taking into account the work of covering cable lines with slabs. At the same time, both when using bricks and when using slabs, it is also important to take into account the number of cables laid in the trenches.

In addition to laying cables in the ground, section 2 of the collection GESNm08 is used for drawing up local resource estimates and local estimates of other types for the construction of urban and industrial transport networks, as well as metro networks.

Information on how to draw up a sample estimate for electrical installation work for outdoor lighting can be obtained by studying Section 5 of Division 2 in the specified installation collection.

An online estimate for electrical installation work, as well as an estimate compiled using specialized programs and software packages, will include the standards from Section 6 if it is necessary to determine the cost of installing cable networks inside buildings and structures. In this section, it is possible to select prices not only for the installation of cables of the internal electrical network, but also for the installation of cable structures of various types.

Sections 7 and 8 of the second section of the collection GESNm08 will help solve such problems as drawing up an estimate for electrical installation work on installing busbars and grounding using various types of conductors.

Basic principles of budgeting

Usually the organization that will carry out the work handles the calculations.
She must coordinate all her actions with the customer. The more detailed all processes and materials are described (down to the number and brand of screws), the better. However, often in practice a simplified version is used, where only the main types of work, units of measurement, quantities, prices and costs of processes are indicated. An example of an estimate for renovation work on a room in an apartment in a simplified version:

No.Title of worksUnitsQuantityPrice for 1 unitCost of work
1Dismantling partitionssq.m.5035017500
2Dismantling the balcony doorPC.111001100
3Installation of partitions (foam blocks)sq.m.5060030000
4Plastering walls and partitionssq.m.20020040000
5Double putty, priming and painting of prepared surfacessq.m.200300034000
6Installation of a balcony doorPC.12703000
7Plastering slopes (windows and doors)sq.m.162504320
8Improvement of slopes (putty, primer, painting)sq.m.164000
Total according to estimate133920

This sample estimate is applicable for making calculations for small-scale projects, and the entered data, if necessary, can easily be adjusted by agreement with the customer. It does not describe exactly how many bags of putty or cans of paint are required to complete the necessary work. The parties agree on the price per unit of measurement and the total cost, and the details (purchase of materials, transportation costs, removal of construction waste) are borne by the contractor.

Let's look at an example of an estimate compiled using a different method. In this case, all the necessary resources to complete the work at each stage are outlined.

At the request of the customer, an estimator or contractor can prepare several versions of estimates, taking into account various components (brand, price and quantity of materials, scope of work, quantity and technical indicators of equipment used, number of workers).

Section 3 of the collection GESNm08 in the estimate for electrical

You can gain an understanding of how to read estimates for electrical installation work of electric power and lighting installations by studying the third section of Section 8 of the GESNm collection. This department has collected many standards related to the installation of electrical machines, current leads to lifting and transport installations and equipment for theatrical and entertainment enterprises.

Among other things, both GESN and FER for electrical installation work on ballasts are located precisely in department 3 of assembly collection 08. Also in this department in both databases there are also standards for low-voltage complete devices such as switchboards, blocks, consoles and control cabinets.

As part of Department 3, it is possible to select prices in the estimate for the installation of machines in the electrical panel. As a rule, this role is most often played by one of the norms of the table GESNm08-03-526.

The estimate for electrical installation often contains standards from Section 5, Division 3 in the specified collection on the EMR. This section contains most of the prices for the installation of switches, sockets, lighting panels and meters.

The installation of lamps with incandescent lamps, fluorescent and mercury lamps is determined in the estimates for electrical installation work with prices also based on the standards from department 3, as well as the installation of electric bells or boxes with step-down transformers.

Estimates for electrical installation work on special installations

Nuclear installations, nuclear power plants and installations in mining workings, due to the specific nature of not only electrical installation work, but also other works of the construction and installation complex, require the preparation of sample estimates for electrical installation work, taking into account all the features of electrical installation work.

If you download the estimate for electrical installation work associated with the special installations listed above, then, most likely, the bulk of the prices will be the norms from sections 4 and 5 of the GESNm08 collection.

Installation of electrical wiring in FER or GESN at nuclear power plants and special buildings of nuclear power plants occurs using the standards from department 4. In this department there are prices not only for the laying of power and control cables in installations of this type, but also standards for the installation of cable couplings, terminations and sealing cable passages.

Estimates for the installation of electrical wiring in mining installations are drawn up using the standards from department 5. It should be noted that this department has an internal division into two sections. Section 1 of Section 5 of the GESNm08 collection contains standards for the installation of cable lines, and using the standards of Section 2, the installation of electrical equipment in mining workings is assessed.

Estimates for electrical installation work on power lines

According to the theory of drawing up estimate documentation for electrical installation devices, estimates for electrical installations are drawn up on the basis of the collection of installation parts GESN or FER 08, which was discussed in more detail above in the text. However, the preparation of estimate forms for the installation of power lines, as a rule, occurs using standards from the collection of the construction part of GESN33.

In this case, both an estimate for temporary power supply and an estimate form for the installation of permanent power lines can be drawn up. However, it should be noted that most often temporary networks are assessed using the standards from installation collections.

In addition, collection 33 is not used to draw up an example estimate for electrical installation work for open wiring, since all the necessary prices are contained in the same installation collection 08.

It is recommended to refer to the GESN33 collection when drawing up estimate forms for overhead power lines. It must be borne in mind that collection 8 for electrical work in the FER, just like the collection in GESN, does not take into account the arrangement of overhead lines.

Samples of estimates for electrical installation work on power lines contain, as a rule, several prices from the 33rd collection. One of these samples is shown in Figure 2.

Figure 2. Sample estimate for electrical work

As you can see in the above calculation of the estimate for electrical installation work, the first position under the code GESN33-01-016-01 is the norm for the installation of supports. It should be noted that from the collection GESN33 it is possible to use both the standards for the installation of steel supports and the standards for the installation of reinforced concrete or wooden supports.

Next, position number 2 in the estimate for electrical installation work is the price for hanging wires. The choice of price should be justified not only by design requirements, but also by the brand and cross-section of the wire. In this article, all prices and volumes in the example estimates are given for demonstration purposes.

Estimate for electrical installation during repair work

An example of an electrical estimate for internal open wiring or hidden wiring can also be drawn up when carrying out repair work on electrical networks. When drawing up estimate forms for repair work, as a rule, tables and norms from the collection of the repair and construction part of GESN under number 67 are used.

If you download a ready-made estimate for electrical installation work, in which the standards from the GESNr67 collection were used, then in this form the most common standards are for the dismantling and replacement of various electrical appliances. For example, the dismantling of switches and sockets, sockets and hangers can be assessed using the standards of table GESNr67-4.

The estimate price for dismantling electrical wiring can be selected in table GESNr67-1. It should be noted that dismantling can be of either hidden wiring or wires with insulators. The cross-section of the wire in this case plays an important role in choosing the appropriate standard.

You can get an idea of ​​how to correctly draw up a sample estimate for electrical installation work when changing various elements of the electrical network by referring to tables GESNr67-5 - GESNr67-7. These tables contain standards for changing lamps, magnetic starters, package switches and lamps. Changing switches and sockets, as well as electricity meters and sockets, can also be assessed using the standards from the indicated tables.

A sample estimate for electrical installation work for the repair of magnetic starters and group panels on the staircase is most often drawn up using tables GESNr67-12 - GESNr67-15.

However, it should be noted that sometimes cases arise that when drawing up estimate forms for dismantling work, there is no suitable norm in the collection GESNr67. This can happen when looking for a quote in the estimate for dismantling electrical panels or dismantling cable structures of various types.

When dismantling a cable laid in different ways, it is also not always possible to select the appropriate price from those available in the GESNr67 collection. In such cases, it is allowed to draw up estimates for electrical installation work using dismantling coefficients applied to installation prices.

Estimate for EOM (Electrical installation work)


Estimate for EOM (Electrical installation work) View estimate

Content

  1. Local estimate: EOM 1
  2. Section: Automation devices
  3. Section: Cabinets
  4. Section: Installation of cable products
  5. Local estimate: EOM 2
  6. Section: Automation devices
  7. Section: Cabinets
  8. Section: Installation of cable products
  9. Local estimate: Power electrical equipment.
  10. Section: Power electrical equipment
  11. Section: Installation of cable products
  12. Local estimate: Electrical installation devices (excluding cost of materials)
  13. Section: Restaurant (excluding kitchen area)
  14. Section: Apart-hotel zones (I,II,IV)

Compiled at the level of current (forecast) prices Coefficients to TSN-2001 MGE No. 156 September 2021. Basis: drawings. Restaurant and terrace, apart-hotel.

Local estimate: EOM 1

Section: Automation devices

  • KNX Client Touch Panel 10″ KNX Client 10″
  • KNX Client Touch Panel 10″ KNX Client 10″ MTN6260-0310 Schneider Electric
  • Mounting kit for 10″ panel Kit MTN6270-5005 Schneider Electric
  • KNX Server plus KNX Server
  • KNX Server plus KNX Server MTN6501-0002 Schneider Electric
  • Setting up KNX Server plus KNX Server
  • KNX bus power supply REG-K/640 MA REG-K/640 MA
  • KNX bus power supply REG-K/640 MA REG-K/640 MA MTN683890 Schneider Electric
  • Power supply DC24/0.4A REG-K, DC24/0.4A REG-K
  • Power supply DC24/0.4A REG-K, DC24/0.4A REG-K MTN693003 Schneider Electric
  • Electric regulators, theater light control unit with a power of 5 kW
  • Universal dimmer LED REG/4×230/250W, 4 channels LED REG/4×230/250W MTN6710-0004 Schneider Electric
  • Actor for switching REG-K/8X230/6, 6 channels REG-K/8X230/6
  • Actor for switching REG-K/8X230/6, 6 channels REG-K/8X230/6 MTN646808 Schneider Electric
  • Presence sensor KNX ARGUS polar white, KNX ARGUS
  • Presence sensor KNX ARGUS polar white, KNX ARGUS MTN630819 Schneider Electric
  • KNX busbar connector, red/DARK gray
  • KNX busbar connector, red/DARK gray MTN689701 Schneider Electric pcs. 19
  • Setting up synchronous digital transmission systems, setting up a monitoring and control system, installing an operating system and software
  • Software graphical configurator KNX + persons. ETS Lite LSS900100 Schneider Electric
  • Functional control group, analog, non-contact, with a total number of elements and settings up to 5

Section: Cabinets

  • Mounted distribution board ShchRn-2x48z-1 74 IP54 UNIVERSAL ShchRn-2x48z-1 74
  • Mounted distribution board ShchRn-2x48z-1 74 IP54 UNIVERSAL ShchRn-2x48z-1 74 IEK

Section: Installation of cable products

  • Vinyl plastic pipes for installed structures, for walls and columns with fastening with staples, internal diameter up to 20 mm
  • Electrical pipes, corrugated, polyvinyl chloride, non-flammable, with probe, outer diameter 20 mm
  • Stainless steel clamps for fastening cable-supporting structures of corrugated pipes with a diameter of 32 mm
  • Tightening of wires and cables into laid pipes and metal sleeves, the first wire is single-core or multi-core in a common braid, total cross-section up to 2.5 mm2
  • Symmetrical cables with copper conductors, fire-resistant, twisted in pairs, with rubber insulation, with an overall screen made of aluminum flex, in a sheath made of a halogen-free polymer composition, brand KPSEng(A)-FRHF, number of pairs and core cross-section 2x2x0.75 mm2
  • Pulling wires and cables into laid pipes and metal sleeves, the first wire is single-core or multi-core in a common braid, total cross-section up to 6 mm2
  • Symmetrical cable with copper cores, core insulation and sheath made of polymer composition UTP-5ng(A)-FRHF, for structured cable systems, voltage 145 V, number of pairs and core diameter 4x2x0.52 mm

Local estimate: EOM 2

Section: Automation devices

  • KNX Client Touch Panel 10″ KNX Client 10″
  • KNX Client Touch Panel 10″ KNX Client 10″ MTN6260-0310 Schneider Electric
  • Mounting kit for 10″ panel Kit MTN6270-5005 Schneider Electric
  • Electric regulators, theater light control unit with a power of 5 kW
  • Universal dimmer LED REG/4×230/250W, 4 channels LED REG/4×230/250W MTN6710-0004 Schneider Electric
  • Universal dimmer LED REG/2×230/250W, 2 channels LED REG/2×230/250W MTN6710-0002 Schneider Electric
  • Actor for switching REG-K/8X230/6, 6 channels REG-K/8X230/6
  • Actor for switching REG-K/8X230/6, 6 channels REG-K/8X230/6 MTN646808 Schneider Electric
  • Presence sensor KNX ARGUS polar white, KNX ARGUS
  • Presence sensor KNX ARGUS polar white, KNX ARGUS MTN630819 Schneider Electric
  • KNX busbar connector, red/DARK gray
  • KNX busbar connector, red/DARK gray MTN689701 Schneider Electric pcs. 19
  • Functional control group, analog, non-contact, with a total number of elements and settings up to 5

Section: Cabinets

  • Mounted distribution board ShchRn-2x48z-1 74 IP54 UNIVERSAL ShchRn-2x48z-1 74
  • Mounted distribution board ShchRn-2x48z-1 74 IP54 UNIVERSAL ShchRn-2x48z-1 74 IEK
  • Wall cabinet dimensions up to 640x840 mm
  • Distribution board mounted white door white for 12 modules IP40 Easy9 EZ9E112P2SRU RU C-RU.AT21.B00033

Section: Installation of cable products

  • Vinyl plastic pipes for installed structures, for walls and columns with fastening with staples, internal diameter up to 20 mm
  • Electrical pipes, corrugated, polyvinyl chloride, non-flammable, with probe, outer diameter 20 mm
  • Stainless steel clamps for fastening cable-supporting structures of corrugated pipes with a diameter of 32 mm
  • Tightening of wires and cables into laid pipes and metal sleeves, the first wire is single-core or multi-core in a common braid, total cross-section up to 2.5 mm2
  • Symmetrical cables with copper conductors, fire-resistant, twisted in pairs, with rubber insulation, with an overall screen made of aluminum flex, in a sheath made of a halogen-free polymer composition, brand KPSEng(A)-FRHF, number of pairs and core cross-section 2x2x0.75 mm2
  • Pulling wires and cables into laid pipes and metal sleeves, the first wire is single-core or multi-core in a common braid, total cross-section up to 6 mm2
  • Symmetrical cable with copper cores, core insulation and sheath made of polymer composition UTP-5ng(A)-FRHF, for structured cable systems, voltage 145 V, number of pairs and core diameter 4x2x0.52 mm

Local estimate: Power electrical equipment.

Section: Power electrical equipment

  • Control units and distribution points (cabinets) with a height of up to 1700 mm, an open control unit with a height and width of up to 1000x800 mm, mounted on the wall
  • Mounted distribution board, IP65 ShchRN-P-72
  • Three-phase meter installed on a finished base
  • Electricity meter three-phase 5-60A, k.t. 1.0, single-tariff electronic LCD on DIN rail
  • Installation switches, automatic (automatic) or non-automatic, one-, two-, three-pole automatic, installed on a structure on a wall or column for a current of up to 100 A
  • Three-pole differential switch, In=50 A, Un ~380 V, 50 Hz, 30 mA, characteristic C Acti 9 iDPN N Vigi3P+N/32/C/30
  • Installation switches, automatic (automatic) or non-automatic, one-, two-, three-pole automatic, installed on a structure on a wall or column for a current of up to 25 A
  • Automatic switch, single-phase, In=10, characteristic C Acti9 IC60N 1Р/10/С
  • Automatic switch, single-phase, In = 16, characteristic C Acti9 IC60N 1P/16/C
  • Control units and distribution points (cabinets) with a height of up to 1700 mm, an open control unit with a height and width of up to 1000x800 mm, mounted on the wall
  • Mounted distribution board, IP65 ShchRN-P-72
  • Three-phase meter installed on a finished base
  • Electricity meter three-phase 5-60A, k.t. 1.0, single-tariff electronic LCD on DIN rail
  • Installation switches, automatic (automatic) or non-automatic, one-, two-, three-pole automatic, installed on a structure on a wall or column for a current of up to 100 A
  • Three-pole differential switch, In=50 A, Un ~380 V, 50 Hz, 30 mA, characteristic C Acti 9 iDPN N Vigi3P+N/32/C/30
  • Installation switches, automatic (automatic) or non-automatic, one-, two-, three-pole automatic, installed on a structure on a wall or column for a current of up to 25 A
  • Automatic switch, single-phase, In=10, characteristic C Acti9 IC60N 1Р/10/С
  • Automatic switch, single-phase, In = 16, characteristic C Acti9 IC60N 1P/16/C
  • Functional control group, analog, non-contact, with a total number of elements and settings up to 5

Section: Installation of cable products

  • Vinyl plastic pipes for installed structures, for walls and columns with fastening with brackets, internal diameter up to 16 mm
  • Corrugated electrical pipes, polyvinyl chloride, non-flammable, with probe, outer diameter 16 mm
  • Plastic holders with a latch for fastening pipes, hoses and flexible bushings with a diameter of 16 mm
  • Vinyl plastic pipes for installed structures, for walls and columns with fastening with staples, internal diameter up to 20 mm
  • Electrical pipes, corrugated, polyvinyl chloride, non-flammable, with probe, outer diameter 20 mm
  • Plastic holders with a latch for fastening pipes, hoses and flexible bushings with a diameter of 20 mm
  • Non-perforated tray 50x300x3000 L=3000
  • Locking steel cable tray, galvanized, non-perforated, without cover, steel thickness 0.7 mm, size 3000x100x50 mm
  • Non-perforated tray 50x200x3000 L=3000
  • Locking steel cable tray, galvanized, non-perforated, without cover, steel thickness 0.7 mm, size 3000x100x50 mm
  • Non-perforated tray 50x100x3000 L=3000
  • Locking steel cable tray, galvanized, non-perforated, without cover, steel thickness 0.7 mm, size 3000x100x50 mm
  • Tightening of wires and cables into laid pipes and metal sleeves, the first wire is single-core or multi-core in a common braid, total cross-section up to 2.5 mm2
  • Power cables with copper cores, voltage 660 V, brand VVGng(A), number of cores and cross-section 3x1.5 mm2
  • Cables on installed structures and trays with installation of branch boxes, two- to four-core cable in rooms with a normal environment with a core cross-section of up to 10 mm2
  • Power cables with copper cores, voltage 660 V, brand VVGng(A), number of cores and cross-section 3x2.5 mm2
  • Wall distribution box on cable with plastic sheath
  • Plastic distribution boxes, for open wiring, 6 terminals, with seals, degree of protection IP55, dimensions 100x100x55 mm
  • LED spotlight with remote control with spotlight weight up to 10 kg
  • LED spotlight Bond Tube Medium, black 17.4 W

Local estimate: Electrical installation devices (excluding cost of materials)

Section: Restaurant (excluding kitchen area)

  • Light control panel
  • Systems that implement control functions, a single-circuit control system for stabilizing a process parameter (regardless of the number of setting parameters) with a positional control law
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • LED spotlight Aledo CM-KID-5-927-FC-BK-TC. Ceiling mount, rotating, dimmable, 2700 K, color - black. Beam angle 15`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • LED spotlight Aledo CM-KID-5-927-FC-BK-TC. Ceiling mount, rotating, dimmable, 2700 K, color - black. Beam angle 20`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Lucelight UPDOWN 3.0. LED IP65 2700K body color white Beam angle 20`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • LED spotlight Aledo CM-KID-5-927-FC-BK-TC. Ceiling mount, rotating, dimmable, 2700 K, color - black. Beam angle 20`
  • Wall lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Rotating lamp in plant pots, LED LEDS C4 AQUA SPOTLIGHT AISI 316 05-9245-CA-37 black dimmable 2700K. Beam angle 15`
  • Hanging lamp
  • Pendant lamp Frandsen Bristol 2700K non-dimmable color: gold
  • Hanging lamp
  • Lamp bain-marie Kocated DH637BK black Infrared lamp
  • Hanging lamp
  • Pendant lamp Paulmann Vintage pendant /Lbvvbhetvsq. 2700K. Decorative grille to order.
  • Wall lamp with screw fastening
  • Sconce 2700K.Color black
  • Spotlight on a support
  • LED floodlight gibus Spotlight 2700K IP68
  • Ceiling fan
  • Ceiling fan Faro Barcelona ALO В=1520 H=380
  • Luminaire with screw fastening for rooms with normal environmental conditions, single lamp
  • Spotlight FLORI 1.1 LED 2700 K, color - white. Beam angle 20`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Lucelight UPDOWN 3.0. LED IP65 2700K body color white Beam angle 15`
  • Floor lamp
  • Built-in luminaire LEDS C4 TAGLIO DI LUCE 55-004-M3-CL dimmable tape 2700K
  • Adjusting the angle of light of lighting fixtures located at a height of 1.8 to 5 m (per lighting fixture)
  • Installation of LED strip
  • LED neon strip s-17
  • Installation of LED strip
  • LED strip S-20
  • Installation of LED strip
  • LED strip in a flexible profile, moisture-resistant S-20
  • Voltage transformers, transformer, voltage up to 10 kV, single-phase
  • Transformer for lighting
  • Manufacturing of lattice structures from pipes
  • Propane-butane gas
  • Seamless hot-deformed steel pipes with chamfered steel grades 15, 20, 25, GOST 8732-78, outer diameter 25 mm, wall thickness 2.8 mm
  • Technical gaseous oxygen
  • Installation of ceiling frames with pendants and fastening parts
  • Tightening of wires and cables into laid pipes and metal sleeves, the first wire is single-core or multi-core in a common braid, total cross-section up to 2.5 mm2
  • Recessed type socket with hidden wiring
  • Single built-in socket 220V
  • Built-in moisture resistant socket 220V
  • Recessed type socket with hidden wiring
  • Built-in double socket 220V
  • Socket block
  • Block of sockets built into furniture 220V
  • Installation of a floor hatch
  • Floor hatch with cable outlet for plant lighting
  • Moisture-resistant floor hatch with cable outlet for illuminating plants
  • Wall-mounted equipment
  • Built-in Aircharge wireless charger

Section: Apart-hotel zones (I,II,IV)

  • Light control panel
  • Systems that implement control functions, a single-circuit control system for stabilizing a process parameter (regardless of the number of setting parameters) with a positional control law
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Rotating LED spotlight LEDS C4 Bond Tube Medium 71-5953-60-00 35-5380-60-OU dimmable, 2700 K, color - black. Beam angle 15`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Rotating LED spotlight LEDS C4 Bond Tube Medium 71-5953-14-00 35-5380-14-OU dimmable, 2700 K, color - white. Beam angle 15`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Rotating LED spotlight LEDS C4 Mini Bond Tube 71-5953-60-00 35-4934-60-OU dimmable, 2700 K, color - black. Beam angle 20`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Rotating LED spotlight LEDS C4 Mini Bond Tube 71-5953-14-00 35-4934-14-OU dimmable, 2700 K, color - white. Beam angle 20`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Rotating LED spotlight LEDS C4 Mini Bond Tube 71-5953-35-00 35-4935-60-OU dimmable, 2700 K, color - black. Beam angle 30`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Rotating LED spotlight LEDS C4 Mini Bond Tube 71-5953-14-00 35-4934-14-OU dimmable, 2700 K, color - white. Beam angle 30`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Rotating LED spotlight AledoMini FOCUS PRO 9, dimmable, 2700 K, color - black. Beam angle 15`
  • Ceiling lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Rotating LED spotlight AledoMini FOCUS PRO 9, dimmable, 2700 K, color - white. Beam angle 15`
  • Wall lamp with screw fastening for rooms with normal environmental conditions, single-lamp
  • Rotary lamp for plants, LEDS C4 AQUA SPOTLIGHT AISI 316 05-9245-CA-37 black dimmable 2700K. Beam angle 15`
  • Lamp in suspended ceilings
  • Built-in LED lamp Aledo RC-ZERO 68-12-9-XX-YY-ZZ-AA black dimmable 2700K. Beam angle 40`
  • Lamp in suspended ceilings
  • Built-in LED lamp Aledo RC-ZERO 68-12-9- XX-YY-ZZ-AA white dimmable 2700K. Beam angle 40`
  • Lamp in suspended ceilings
  • Built-in LED rotary lamp Lumitex EVA OK black dimmable 2700K. Beam angle 33`
  • Lamp in suspended ceilings
  • Built-in LED lamp Molto luce BADO R 445-06321415 dimmable 2700K
  • Wall lamp with screw fastening
  • Sconce Stars dimmable 2700K
  • Wall lamp with screw fastening
  • Wall lamp LEDS C4 COSMOS LED 05-9955-Z5-CL
  • Ceiling fan
  • Ceiling fan Faro Barcelona ALO В=1520 H=380
  • Adjusting the angle of light of lighting fixtures located at a height of 1.8 to 5 m (per lighting fixture)
  • Installation of LED strip
  • Dimmable LED strip s-18
  • Installation of LED strip
  • LED strip in a flexible profile, dimmable S-19
  • Voltage transformers, transformer, voltage up to 10 kV, single-phase
  • Transformer for lighting
  • Recessed type socket with hidden wiring
  • Socket built into furniture 220V
  • Recessed type socket with hidden wiring
  • Protected socket 220V
  • Recessed type socket with hidden wiring
  • Internet socket RJ-45
  • Recessed type socket with hidden wiring
  • TV socket RJ-45
  • Socket block
  • Block of sockets built into furniture 220V
  • Installation of a floor hatch
  • Floor hatch with cable outlet for plant lighting
  • Wall-mounted equipment
  • Built-in Aircharge wireless charger
Rating
( 1 rating, average 4 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]